Lutron LCR-9183 is a handheld precision LCR meter with a 19,999/1,999 counts dual LCD. It measures L, C and R in serial or parallel mode with D/Q/θ/ESR at five test frequencies from 100 Hz to 100 KHz, offers AutoLCR smart check, open/short calibration and an RS232/USB PC interface.
The Lutron LCR-9183 is a handheld precision LCR meter with a 19,999/1,999 counts dual LCD display. The primary display shows the inductance, capacitance or resistance of the device under test, while the secondary display shows the dissipation factor (D), quality factor (Q), phase angle (θ) or equivalent series resistance (ESR).
Five test frequencies are available — 100 Hz, 120 Hz, 1 KHz, 10 KHz and 100 KHz — with a typical AC test signal level of 0.6 V rms. In the default AutoLCR mode the meter checks the type of impedance and enters the L, C or R measurement automatically; Auto-L, Auto-C, Auto-R and DCR modes can also be selected. Serial or parallel mode is chosen automatically according to the measured impedance (parallel above 10 KΩ, serial below 10 KΩ) or set manually with the SER/PAL key.
Open/Short calibration improves accuracy on high and low impedances, the REL/% mode compares components against a reference value as a percentage, and readings can be sent to a PC through the RS232/USB interface. The meter runs on a 006P DC 9V battery or an optional DC 9V power adapter.
| Manufacturer | Lutron |
|---|---|
| Model | LCR-9183 |
| Display | Dual LCD, 19,999/1,999 counts; LCD size 66.8 x 52.8 mm |
| Test frequency | 100 Hz / 120 Hz / 1 KHz / 10 KHz / 100 KHz |
| Test AC signal level | 0.6 V rms typically |
| Measurement parameters | Ls/Lp/Cs/Cp/Rs/Rp and DCR, with D/Q/θ/ESR |
| Dissipation factor (D) | 0.000 to 1999 |
| Quality factor (Q) | 0.000 to 1999 |
| θ measurement | ± 90° |
| DCR mode | 1.00 Ω to 200.0 MΩ |
| Resistance ranges | 20 Ω, 200 Ω, 2 KΩ, 20 KΩ, 200 KΩ, 2 MΩ, 20 MΩ, 200 MΩ |
| Capacitance ranges | 20 pF, 200 pF, 2000 pF, 20 nF, 200 nF, 2000 nF, 20 uF, 200 uF, 2000 uF, 20 mF |
| Inductance ranges | 20 uH, 200 uH, 2000 uH, 20 mH, 200 mH, 2000 mH, 20 H, 200 H, 2000 H |
| Accuracy reference temperature | 23 ± 5 °C |
| Accuracy — Resistance (DCR) | 20 Ω to 2 MΩ: ±(0.8% + 5d); 20 MΩ: ±(1.5% + 5d); 200 MΩ: ±(2.5% + 5d) |
| Accuracy — Resistance (Rp/Rs), 100 Hz/120 Hz | 20 Ω: ±(1.2% + 5d); 200 Ω to 200 KΩ: ±(0.8% + 5d); 2 MΩ and 20 MΩ: ±(1.5% + 5d); 200 MΩ: ±(2.5% + 5d) |
| Accuracy — Resistance (Rp/Rs), 1000 Hz | 20 Ω: ±(1.2% + 5d); 200 Ω to 200 KΩ: ±(0.8% + 5d); 2 MΩ: ±(1.5% + 5d); 20 MΩ: ±(2.5% + 5d); 200 MΩ: ±(6% + 5d) |
| Accuracy — Resistance (Rp/Rs), 10 KHz | 20 Ω: ±(1.2% + 5d); 200 Ω to 200 KΩ: ±(0.8% + 5d); 2 MΩ: ±(1.5% + 5d); 20 MΩ: ±(2.5% + 5d) |
| Accuracy — Resistance (Rp/Rs), 100 KHz | 20 Ω: ±(2.5% + 5d); 200 Ω to 200 KΩ: ±(0.8% + 5d); 2 MΩ: ±(3% + 5d); 20 MΩ: not specified |
| Accuracy — Capacitance (Cp/Cs, D ≤ 0.1), 100 Hz/120 Hz | 20 pF: ±(2.5% + 5d); 200 pF: ±(1.5% + 5d); 2000 pF: ±(1.2% + 5d); 20 nF to 200 uF: ±(1.0% + 5d); 2000 uF: ±(2% + 5d); 20 mF: ±(3% + 5d) |
| Accuracy — Capacitance (Cp/Cs, D ≤ 0.1), 1000 Hz | 20 pF to 2000 pF: ±(1.5% + 5d); 20 nF to 200 uF: ±(1% + 5d); 2000 uF: ±(2% + 5d); 20 mF: not specified |
| Accuracy — Capacitance (Cp/Cs, D ≤ 0.1), 10 KHz | 20 pF: ±(1.5% + 5d); 200 pF to 2000 nF: ±(1.0% + 5d); 20 uF: ±(1.5% + 5d); 200 uF: ±(2% + 5d) |
| Accuracy — Capacitance (Cp/Cs, D ≤ 0.1), 100 KHz | 20 pF: ±(1.5% + 5d); 200 pF to 2000 nF: ±(1.0% + 5d); 20 uF: ±(1.5% + 5d); 200 uF: not specified |
| Accuracy — Inductance (Lp/Ls, D ≤ 0.1), 100 Hz/120 Hz | 20 uH to 2000 uH: ±(1.5% + 5d); 20 mH to 200 H: ±(1.0% + 5d); 2000 H: ±(2% + 5d) |
| Accuracy — Inductance (Lp/Ls, D ≤ 0.1), 1000 Hz | 20 uH to 2000 uH: ±(1.5% + 5d); 20 mH to 20 H: ±(1.0% + 5d); 200 H: ±(1.5% + 5d); 2000 H: not specified |
| Accuracy — Inductance (Lp/Ls, D ≤ 0.1), 10 KHz | 20 uH and 200 uH: ±(1.5% + 5d); 2000 uH to 2000 mH: ±(1.0% + 5d) |
| Accuracy — Inductance (Lp/Ls, D ≤ 0.1), 100 KHz | 20 uH and 200 uH: ±(1.5% + 5d); 2000 uH to 200 mH: ±(1.0% + 5d); 2000 mH: not specified |
| Accuracy remark | Open/Short calibration is required for the lowest and highest ranges (marked After calibration in the manual) |
| Serial / parallel mode | Auto selected: parallel (Lp/Cp/Rp) above 10 KΩ, serial (Ls/Cs/Rs) below 10 KΩ; manual selection by SER/PAL key |
| Calibration | Open/Short calibration |
| Data hold | Freezes the display reading |
| Data output | RS232/USB PC computer interface, 9600 bps |
| Power off | Auto shut off (after 5 minutes without key operation) or manual off by push button |
| Operating temperature | 0 to 50 °C |
| Operating humidity | Less than 85% R.H. |
| Power supply | 006P DC 9V battery (alkaline or heavy duty type) or DC 9V adapter input (AC/DC power adapter is optional) |
| Power consumption | Approx. DC 35 mA |
| Dimensions | 193 x 88 x 41 mm |
| Weight | 382 g (meter only) |