Industrial & Scientific

ETI Pro-Surface Thermapen 231-279 Surface Thermometer for Grills & Hotplates, -49.9 to 299.9 °C, 0.1/1 °C Resolution, Fold-Away Probe

Brand: eti
14,100 EGP

The ETI Pro-Surface Thermapen 231-279 is a fold-away surface thermometer for grills, hotplates and other hot surfaces. It measures -49.9 to 299.9 °C with user-selectable 0.1 or 1 °C resolution and ±0.4 °C accuracy from -49.9 to 199.9 °C (±1 °C otherwise). Made in Britain.

Quantity:
– +

ETI Pro-Surface Thermapen 231-279 Surface Thermometer

The Pro-Surface Thermapen 231-279 from Electronic Temperature Instruments (ETI) is a professional thermometer for measuring the temperature of grills, griddles, hotplates and other flat surfaces. Its flat-bottomed probe tip rests on the surface being measured, and the pivoting tip helps keep it in full contact. It covers -49.9 to 299.9 °C with an accuracy of ±0.4 °C from -49.9 to 199.9 °C and ±1 °C otherwise.

There is no on/off button: unfold the probe and the instrument switches on; fold it back into its rubber retainer and it switches off. The resolution (0.1 °C or 1 °C) and the 10-minute auto-off are set with small slide switches under the battery cover. The plastic contains the Biomaster additive, and the instrument is made in Britain under ETI's BS EN ISO 9001 quality system.

The thermometer is supplied with a traceable certificate of calibration and a protective pouch (830-001). For high-temperature work, a protective silicone rubber boot can be ordered for added thermal and drop protection.

Key Features

  • Measuring range -49.9 to 299.9 °C
  • Accuracy ±0.4 °C from -49.9 to 199.9 °C, ±1 °C otherwise
  • User-selectable resolution: 0.1 °C (factory default) or 1 °C
  • Switches on and off by unfolding and folding the probe, for one-handed operation
  • Pivoting surface probe with flat-bottomed tip for good surface contact
  • Auto-off after 10 minutes (factory default), can be disabled
  • Lo / Hi / Err messages for out-of-range readings and probe faults
  • Splash-proof body designed for industrial use
  • Biomaster additive in the plastic material
  • Suitable for use within HACCP plans; complies with EC Reg 1935/2004 and EU Reg 10/2011 for food contact
  • Powered by two CR2032 3V batteries with low-battery indicator
  • Made in Britain, CE and UKCA marked

Product Specifications

ManufacturerElectronic Temperature Instruments Ltd (ETI)
Model231-279
ProductPro-Surface Thermapen® Thermometer
Measuring Range-49.9 to 299.9 °C
Resolution0.1 °C or 1 °C, user selectable (factory default 0.1 °C)
Accuracy±0.4 °C from -49.9 to 199.9 °C; otherwise ±1 °C
ProbeFold-away surface probe with flat-bottomed tip; do not rotate more than 180 degrees
On / OffBy unfolding / folding the probe
Auto-off10 minutes (factory default), can be disabled
Display MessagesLo (below range), Hi (above range), Err (probe fault)
Power Supply2 × CR2032 3V batteries, low-battery symbol
MaterialPlastic containing Biomaster additive
Food ContactEC Reg 1935/2004; EU Reg 10/2011 & amendment 2020/1245; suitable for use within HACCP plans
ComplianceRoHS & REACH; Directive 2011/65/EU & amendment 2015/863; EU Reg 2014/35/EU; EU Reg 2014/30/EU; CE / UKCA
Quality SystemBS EN ISO 9001 (ETI Limited)
Country of OriginMade in Britain

Write a Review

Your email address will not published. Required fieled are marked

Your Review:

Files to download

Easy Test whatsapp
Cart :
Subtotal
$480

The maximum purchase for this product is () pieces.

| Compare List ()