Lutron LCR-9184 professional LCR meter measuring L, C and R at 100 Hz, 120 Hz, 1 kHz, 10 kHz and 100 kHz, with D/Q/θ/ESR, DCR mode up to 200.0 MΩ, AutoLCR, sorting mode, open/short calibration, 19,999-count dual backlit LCD, RS232/USB output and auto power off.
The Lutron LCR-9184 is a professional LCR meter that measures inductance, capacitance and resistance at five selectable test frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz and 100 kHz. It handles both series and parallel equivalent circuits (Ls/Lp/Cs/Cp/Rs/Rp) together with the secondary parameters D, Q, θ and ESR, and adds a DC resistance (DCR) mode from 1.00 Ω to 200.0 MΩ.
An AutoLCR smart check simplifies everyday measurement, and the sorting mode checks components against tolerances from ± 0.25 % up to ± 20 % or +80 % -20 %. Open and short calibration compensate for test leads and fixtures, and the test AC signal level is typically 0.6 V rms.
Readings are shown on a 19,999/1,999-count dual LCD with green backlight and can be sent to a PC through the RS232/USB interface. The meter runs on a 006P DC 9V battery or an optional DC 9V adapter, with auto power off and a multi-level battery detector.
| Manufacturer | Lutron |
|---|---|
| Model | LCR-9184 |
| Test frequencies | 100 Hz / 120 Hz / 1 kHz / 10 kHz / 100 kHz |
| Measurement parameters | Ls/Lp/Cs/Cp/Rs/Rp with D/Q/θ/ESR; DCR mode; serial/parallel selectable; AutoLCR smart check |
| Test range (at 1 kHz) | L: 200.00 uH to 2000.0 H; C: 2000.0 pF to 2.000 mF; R: 20.000 Ω to 200.0 MΩ |
| DCR range | 1.00 Ω to 200.0 MΩ |
| Test AC signal level | 0.6 V rms typically |
| Display | 19,999/1,999 counts dual LCD; LCD size 56.4 x 52.9 mm; green backlight (ON/OFF) |
| Dissipation factor (D) | 0.000 to 999 |
| Quality factor (Q) | 0.000 to 999 |
| θ measurement | ± 90° |
| Sorting tolerance mode | ± 0.25 %, ± 0.5 %, ± 1 %, ± 2 %, ± 5 %, ± 10 %, ± 20 %, +80 % -20 % |
| Calibration | Open/Short calibration |
| Data hold | Freezes the display reading |
| Data output | RS232/USB PC computer interface |
| Power off | Auto shut off or manual off by push button |
| Accuracy reference temperature | 23 ± 5 °C |
| DCR accuracy, 20 Ω range | ±(0.5 % + 5 d); after short calibration |
| DCR accuracy, 200 Ω range | ±(0.5 % + 5 d) |
| DCR accuracy, 2 kΩ range | ±(0.5 % + 5 d) |
| DCR accuracy, 20 kΩ range | ±(0.5 % + 5 d) |
| DCR accuracy, 200 kΩ range | ±(0.5 % + 5 d) |
| DCR accuracy, 2 MΩ range | ±(0.5 % + 5 d); after open calibration |
| DCR accuracy, 20 MΩ range | ±(1 % + 5 d); after open calibration |
| DCR accuracy, 200 MΩ range | ±(2 % + 5 d); after open calibration |
| Resistance Rp/Rs accuracy, 20 Ω range | 100/120 Hz: ±(1 % + 5 d); 1 kHz: ±(1 % + 5 d); 10 kHz: ±(1 % + 5 d); 100 kHz: ±(2 % + 5 d); after short calibration |
| Resistance Rp/Rs accuracy, 200 Ω range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Resistance Rp/Rs accuracy, 2 kΩ range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Resistance Rp/Rs accuracy, 20 kΩ range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Resistance Rp/Rs accuracy, 200 kΩ range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Resistance Rp/Rs accuracy, 2 MΩ range | 100/120 Hz: ±(1 % + 5 d); 1 kHz: ±(1 % + 5 d); 10 kHz: ±(1 % + 5 d); 100 kHz: ±(2 % + 5 d); after open calibration |
| Resistance Rp/Rs accuracy, 20 MΩ range | 100/120 Hz: ±(1 % + 5 d); 1 kHz: ±(2 % + 5 d); 10 kHz: ±(2 % + 5 d); after open calibration |
| Resistance Rp/Rs accuracy, 200 MΩ range | 100/120 Hz: ±(2 % + 5 d); 1 kHz: ±(5 % + 5 d); after open calibration |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 20 pF range | 100/120 Hz: ±(2 % + 5 d); 1 kHz: ±(1 % + 5 d); 10 kHz: ±(1 % + 5 d); 100 kHz: ±(1 % + 5 d); after open calibration |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 200 pF range | 100/120 Hz: ±(1 % + 5 d); 1 kHz: ±(1 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d); after open calibration |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 2000 pF range | 100/120 Hz: ±(0.8 % + 5 d); 1 kHz: ±(0.8 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d); after open calibration |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 20 nF range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 200 nF range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 2000 nF range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 20 uF range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.8 % + 5 d); 100 kHz: ±(0.8 % + 5 d) |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 200 uF range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(1 % + 5 d); after short calibration |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 2000 uF range | 100/120 Hz: ±(1 % + 5 d); 1 kHz: ±(1 % + 5 d); after short calibration |
| Capacitance Cp/Cs accuracy (D ≤ 0.1), 20 mF range | 100/120 Hz: ±(2 % + 5 d); after short calibration |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 20 uH range | 100/120 Hz: ±(1 % + 5 d); 1 kHz: ±(1 % + 5 d); 10 kHz: ±(1 % + 5 d); 100 kHz: ±(1 % + 5 d); after short calibration |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 200 uH range | 100/120 Hz: ±(1 % + 5 d); 1 kHz: ±(1 % + 5 d); 10 kHz: ±(0.8 % + 5 d); 100 kHz: ±(0.8 % + 5 d); after short calibration |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 2000 uH range | 100/120 Hz: ±(0.8 % + 5 d); 1 kHz: ±(0.8 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 20 mH range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d); 100 kHz: ±(0.5 % + 5 d) |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 200 mH range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d) |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 2000 mH range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d); 10 kHz: ±(0.5 % + 5 d) |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 20 H range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.5 % + 5 d) |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 200 H range | 100/120 Hz: ±(0.5 % + 5 d); 1 kHz: ±(0.8 % + 5 d) |
| Inductance Lp/Ls accuracy (D ≤ 0.1), 2000 H range | 100/120 Hz: ±(1 % + 5 d); after open calibration |
| Operating temperature | 0 to 50 °C |
| Operating humidity | Less than 85 % RH |
| Power supply | 006P DC 9V battery (alkaline or heavy duty type); DC 9V adapter input (AC/DC power adapter optional) |
| Power consumption | DC 16 mA approximately (LCD backlight off) |
| Standards | ISO-9001, CE, IEC1010 |
| Dimensions | 193 x 88 x 41 mm |
| Weight | 420 g (meter only) |
Your email address will not published. Required fieled are marked