The EasySyS ES-PAR2500 measures Photosynthetically Active Radiation (PPFD) over 400–700 nm with a 0–2500 µmol/m²·s range, ±2% accuracy, 1 µmol/m²·s resolution and <1 s response. Cosine-corrected, with RS485 Modbus RTU, 4–20 mA, voltage or SDI-12 output.

EasySyS ES-PAR2500 PAR Quantum Light Sensor

The ES-PAR2500 measures Photosynthetically Active Radiation (PAR) — the 400–700 nm band of sunlight that plants use for photosynthesis. A precision optical detector behind a 400–700 nm optical filter produces a signal proportional to the incident radiation, with a cosine-corrected response to the angle of incoming light.

Readings are delivered directly as photosynthetic photon flux density in µmol/m²·s, ready for any data logger, controller or PLC. The sensor is built for continuous 24/7 outdoor service, with a weather-resistant polymer housing and simple flange mounting on masts and brackets.

A choice of outputs — RS485 Modbus RTU, 4–20 mA, 0–2 / 0–5 / 0–10 V or SDI-12 — lets one sensor fit greenhouse automation, agro-meteorological stations and research platforms alike.

Key features

  • True PAR measurement: 400–700 nm optical filter with direct readout in µmol/m²·s.
  • High accuracy: ±2 % accuracy with 1 µmol/m²·s resolution over the full 0–2500 range.
  • Fast response: response time below 1 second, tracking passing clouds and rapid light changes.
  • Long-term stability: drift below ±2 % per year for multi-season datasets.
  • Choice of outputs: RS485 Modbus RTU, 4–20 mA, 0–2 / 0–5 / 0–10 V or SDI-12.
  • Wide temperature range: operates from −30 °C to +75 °C.
  • Simple flange mounting for quick, level installation.
  • Good unit-to-unit interchangeability — replace or add sensors without re-engineering.
  • In the box: sensor in the selected output version, 2 m pre-wired signal cable and user manual with Modbus protocol.

Product Specifications

ManufacturerEasySyS
ModelES-PAR2500
Measured parameterPhotosynthetically Active Radiation (PPFD)
Measuring range0 – 2500 µmol/m²·s
Resolution1 µmol/m²·s
Accuracy±2 %
Spectral response400 – 700 nm
Response time< 1 s
Long-term stability< ±2 % change per year
Angular responseCosine-corrected
DetectorPrecision optical detector with 400–700 nm optical filter
Output options (choose one)RS485 Modbus RTU · 4–20 mA · 0–2 V · 0–5 V · 0–10 V · SDI-12
Supply — RS485, SDI-12, 0–2 V5 – 24 VDC
Supply — 0–5 V, 0–10 V, 4–20 mA12 – 24 VDC
Modbus settings9600 bps, 8 data bits, no parity, 1 stop bit · default address 01
Analog conversionPAR = 1250 × V (0–2 V) · 500 × V (0–5 V) · 250 × V (0–10 V) · 156.25 × I − 625 (4–20 mA)
Operating temperature−30 °C to +75 °C
Housing materialDurable weather-resistant polymer
MountingFlange installation
Cable2 m standard — 3-wire (analog) / 4-wire (RS485); custom lengths on request
In the boxSensor (selected output version), 2 m pre-wired signal cable, user manual incl. Modbus protocol