The Delta-T WET150 is an accurate digital multi-parameter SDI-12 sensor measuring water content, electrical conductivity and temperature in soils, composts and growing media, with ten pre-configured measurement sets and fully customisable parameters, units and soil calibrations.
The WET150 is an accurate and highly versatile digital multi-parameter sensor that measures water content, electrical conductivity and temperature in soils, composts and artificial growing media from a single insertion.
It can be used individually with an SDI-12 meter or as a networked group of sensors with any logger or controller supporting SDI-12 communication; an SDI-12 network can address up to 62 sensors. The Delta-T GP2 logger and controller is ideally suited to networked WET150 applications.
The WET150 offers ten pre-configured measurement sets (aM! and aM1!…aM9!) as sequential or concurrent measurements, with or without CRC error checking. Sets aM! to aM8! can be customised for parameter order, units, soil calibrations and EC temperature compensation, while aM9! is a fixed native format (permittivity, bulk EC, temperature) for Delta-T loggers and meters.
| Manufacturer | Delta-T Devices Ltd |
|---|---|
| Model | WET150 |
| Measured parameters | Water content, electrical conductivity, temperature |
| Native output parameters | Ɛr (real relative permittivity), ECb (bulk EC) in mS.m-1, Temperature in °C |
| Available output parameters | Ɛr, water content in % or m3.m-3, ECb, ECp at soil temperature, ECp compensated to reference temperature, temperature in °C or °F, square root permittivity |
| Communication | SDI-12, conforms to SDI-12 specification version 1.3 (CRC error checking supported) |
| Network capacity | Up to 62 sensors per SDI-12 network |
| Measurement sets | 10 pre-configured sets (aM! and aM1!…aM9!), sequential or concurrent; aM!–aM8! customisable, aM9! fixed |
| Generic soil calibrations | Mineral (a0 1.6, a1 8.4), Organic (1.3, 7.7), PeatMix (1.16, 7.09), Coir (1.16, 7.41), MinWool (1.04, 7.58), Perlite (1.06, 6.53), Custom |
| Custom calibration ranges | a0: 1.00 to 5.00; a1: 3.00 to 15.00 |
| EC soil parameter | Default 4.1; valid range 0.00 to 10.00 |
| EC compensation temperature | Default 25°C; valid range 0.00 to 100.00 °C |
| EC temperature coefficient | Default 2%/°C linear; valid range 0.00 to 10.00 %/°C |
| EC units | S.m-1, dS.m-1, mS.cm-1, mS.m-1 (default), µS.cm-1 |
| Lower soil moisture limit for ECp (soil parameter 4.1) | Mineral 12.67%, Organic 17.72%, PeatMix 21.22%, Coir 20.30%, MinWool 21.43%, Perlite 24.57% |
| Error code (ECp not calculable) | -8020 |