Lutron DW-6093 3-Phase Power Analyzer, True RMS, 10 to 600 ACV, up to 1200 A with CP-1201 Clamps, SD Card Real-Time Data Recorder, RS232/USB

Brand: Lutron
Out of Stock

The Lutron DW-6093 is a True RMS 3-phase power analyzer for 1P/2W, 1P/3W, 3P/3W and 3P/4W systems. It measures 10 to 600 ACV, current up to 1200 A with three CP-1201 clamp probes, power, energy, power factor, phase angle and frequency, and records to an SD card.

Lutron DW-6093 3-Phase Power Analyzer with SD Card Data Recorder

The Lutron DW-6093 is a 3-phase power analyzer for multi-power systems: 1P/2W, 1P/3W, 3P/3W and 3P/4W. Voltage and current are measured as True RMS values, with a voltage range of 10 to 600 ACV (auto range) and current ranges of 20 A, 200 A and 1200 A using the three supplied CP-1201 clamp probes. The meter also accepts universal current probes, including the optional 3000 A flexible probe CP-3000.

Beyond voltage and current, the analyzer measures true power (KW, MW, GW), apparent power (KVA, MVA, GVA), reactive power (KVAR, MVAR, GVAR), watt-hour values (WH, SH, QH, PFH), power factor, phase angle and frequency, with programmable CT ratio (1 to 600) and PT ratio (1 to 1000).

A built-in clock and calendar stamp every reading saved to the SD memory card, with a sampling time settable from 2 to 7200 seconds. Slot the SD card into a computer and the measured values, with year/month/date/hour/minute/second, open directly in Excel for further analysis. Warranty: 1 year.

Key Features

  • Analysis of 1P/2W, 1P/3W, 3P/3W and 3P/4W power systems
  • True RMS voltage and current measurement
  • Voltage measurement range: 10 to 600 ACV, auto range; ACV input impedance 10 Mega ohms
  • Current ranges 20 A / 200 A / 1200 A with the supplied CP-1201 clamp probes
  • True, apparent and reactive power; WH, SH, QH and PFH; power factor, phase angle and frequency
  • Programmable CT ratio (1 to 600) and PT ratio (1 to 1000)
  • Real-time data recorder on SD memory card with built-in clock and calendar; sampling time 2 to 7200 seconds
  • Recorded data opens directly in Excel with full time information
  • Dot matrix LCD, 320 X 240 pixels, with back light
  • RS232/USB computer data output with the optional USB-01 or UPCB-02 cable and SW-U811-WIN software
  • Safety standard: IEC 1010, CAT III 600V

Package Contents

  • DW-6093 power analyzer
  • Test leads (TL88-4AT), 1 set (4 PCs)
  • Alligator clips (TL88-4AC), 1 set (4 PCs)
  • Clamp probe (CP-1201), 3 PCs
  • AC to DC 9V adapter
  • 2 G SD memory card
  • Carrying bag
  • Instruction manual

Optional Accessories

  • 2000 Amp current probe, CP-2000
  • 200 Amp current probe, CP-200
  • Flexible 3000 Amp current probe, CP-3000
  • USB cable, USB-01
  • RS232 cable, UPCB-02
  • Data acquisition software, SW-U811

Product Specifications

ManufacturerLutron Electronic
ModelDW-6093
Wire Connections1P/2W, 1P/3W, 3P/3W, 3P/4W
MeasurementsACV, ACA, true power, apparent power, reactive power, power factor, phase angle, frequency, watt-hour (WH, SH, QH, PFH)
AC Voltage (True RMS)Range: 10.0V to 600.0V (phase to neutral line and phase to phase), auto range; Resolution: 0.1V; Accuracy: ± (0.5%+0.5V)
AC Current, 20A RangeResolution: 0.001A (< 10 A), 0.01A (≥ 10 A); Accuracy: Meter + CP-1201 ± (1 %+0.1A), Meter only ± (0.5 %+0.02A)
AC Current, 200A RangeResolution: 0.01A (< 100 A), 0.1A (≥ 100 A); Accuracy: Meter + CP-1201 ± (1 %+0.5A), Meter only ± (0.5 %+0.2A)
AC Current, 1200A RangeResolution: 0.1A (< 1000 A), 1A (≥ 1000 A); Accuracy: Meter + CP-1201 ± (1 %+5A), Meter only ± (0.5 %+2A)
Current Probe Input Signal Voltage (ACV)200 mV / 300 mV / 500 mV / 1 V / 2 V / 3 V
Current Probe Input Current Range (ACA)20 A / 200 A / 2000 A (1200 A) / 30 A / 300 A / 3000 A; the meter can cooperate with universal current probes
Power FactorRange: 0.00 to 1.00; Resolution: 0.01; Accuracy: ± 0.04
Phase AngleRange: -180° to 180°; Resolution: 0.1°; Accuracy: ± 1° (ACOS (PF))
FrequencyRange: 45 to 65 Hz; Resolution: 0.1 Hz; Accuracy: 0.1 Hz
Active (Real) Power0.000 to 9.999 KW: resolution 0.001/0.01/0.1 KW, accuracy ± (1%+0.008KW) — 10.00 to 99.99 KW: resolution 0.01/0.1 KW, accuracy ± (1%+0.08KW) — 100.0 to 999.9 KW: resolution 0.1 KW, accuracy ± (1%+0.8KW) — 1.000 to 9.999 MW: resolution 0.001 MW, accuracy ± (1%+0.008MW) — The resolution changes according to the ACA range
Apparent Power0.000 to 9.999 KVA: resolution 0.001/0.01/0.1 KVA, accuracy ± (1%+0.008KVA) — 10.00 to 99.99 KVA: resolution 0.01/0.1 KVA, accuracy ± (1%+0.08KVA) — 100.0 to 999.9 KVA: resolution 0.1 KVA, accuracy ± (1%+0.8KVA) — 1.000 to 9.999 MVA: resolution 0.001 MVA, accuracy ± (1%+0.008MVA) — The resolution changes according to the ACA range
Reactive Power0.000 to 9.999 KVAR: resolution 0.001/0.01/0.1 KVAR, accuracy ± (1%+0.008 KVAR) — 10.00 to 99.99 KVAR: resolution 0.01/0.1 KVAR, accuracy ± (1%+0.08 KVAR) — 100.0 to 999.9 KVAR: resolution 0.1 KVAR, accuracy ± (1%+0.8 KVAR) — 1.000 to 9.999 MVAR: resolution 0.001 MVAR, accuracy ± (1%+0.008 MVAR) — The resolution changes according to the ACA range
Watt Hour (Active Power Hour): WH0.000 to 9.999 KWH: resolution 0.001 KWH, accuracy ± (2%+0.008 KWH) — 10.00 to 99.99 KWH: resolution 0.01 KWH, accuracy ± (2%+0.08 KWH) — 100.0 to 999.9 KWH: resolution 0.1 KWH, accuracy ± (2%+0.8 KWH) — 1.000 to 9.999 MWH: resolution 0.001 MWH, accuracy ± (2%+0.008 MWH)
VA Hour (Apparent Power Hour): SH0.000 to 9.999 KVAH: resolution 0.001 KVAH, accuracy ± (2%+0.008 KVAH) — 10.00 to 99.99 KVAH: resolution 0.01 KVAH, accuracy ± (2%+0.08 KVAH) — 100.0 to 999.9 KVAH: resolution 0.1 KVAH, accuracy ± (2%+0.8 KVAH) — 1.000 to 9.999 MVAH: resolution 0.001 MVAH, accuracy ± (2%+0.008 MVAH)
VAR Hour (Reactive Power Hour): QH0.000 to 9.999 KVARH: resolution 0.001 KVARH, accuracy ± (2%+0.008 KVARH) — 10.00 to 99.99 KVARH: resolution 0.01 KVARH, accuracy ± (2%+0.08 KVARH) — 100.0 to 999.9 KVARH: resolution 0.1 KVARH, accuracy ± (2%+0.8 KVARH) — 1.000 to 9.999 MVARH: resolution 0.001 MVARH, accuracy ± (2%+0.008 MVARH)
CT / PT RatioProgrammable CT ratio 1 to 600; PT ratio 1 to 1000
ACV Input Impedance10 Mega ohms
Range SelectACV: auto range; ACA: manual range
Overload ProtectionACV: 720 ACV rms; ACA: 1300 ACA with clamp probe CP-1201
Clamp Frequency Response40 Hz to 1 KHz
Spec. Tested Frequency45 to 65 Hz
Sampling TimeApprox. 1 second
Data LoggerReal-time recording to SD memory card with year/month/date/hour/minute/second, downloadable to Excel; sampling time 2 seconds to 7200 seconds in 2-second steps
DisplayDot matrix LCD (320 X 240 pixels) with back light; LCD size 81.4 X 61 mm (3.2 X 2.4 inch)
Data OutputRS232/USB computer interface (optional USB cable USB-01 or RS232 cable UPCB-02)
Safety StandardIEC1010 CAT III 600 V
CertificationsISO-9001, CE, IEC1010
Operating Temperature0 to 50 ℃ (32 to 122 ℉)
Operating HumidityLess than 80% R.H.
Power SupplyDC 1.5V, AA (UM-3) battery X 8 PCs (alkaline or heavy-duty battery); AC to DC 9V power adapter
Power ConsumptionMeter: 300 DCmA; Clamp: 34 DCmA
Clamp Max. Conductor Size50 mm (2.0 inch) Dia. (clamp CP-1201)
DimensionsMeter: 225 X 125 X 64 mm (8.86 X 4.92 X 2.52 inch); Clamp: 210 X 64 X 33 mm (8.3 X 2.5 X 1.3 inch); Clamp jaw: 86 mm (3.4 inch) outside
WeightMeter: 948g (includes batteries); Clamp (including cable): 467g