Electrical & Electronic

Lutron DW-6195 3 Phase Power Analyzer with Harmonic Measurement, SD Card Real Time Data Recorder, 10 to 600 ACV, 1P/2W to 3P/4W, TFT LCD

Brand: Lutron
180,000 EGP

The Lutron DW-6195 is a 3 phase power analyzer with harmonic measurement for 1P/2W, 1P/3W, 3P/3W and 3P/4W systems. It measures 10 to 600 ACV, current with the three included CP-1201 clamp probes, power, energy, power factor and harmonics, and records in real time to an SD card.

Quantity:
– +

Lutron DW-6195 3 Phase Power Analyzer with Harmonic Measurement

The Lutron DW-6195 is a 3 phase power analyzer with harmonic measurement and a TFT LCD (320 X 240 pixels) with back light. It analyses 1P/2W, 1P/3W, 3P/3W and 3P/4W systems, measuring voltage from 10 ACV to 600 ACV, current through the three included CP-1201 clamp probes, active, apparent and reactive power, energy, power factor, phase angle and frequency.

Beyond the basic power parameters, the analyzer displays harmonics from the 1st to the 50th order together with the waveform, Total Harmonic Distortion (THD), a graphic phase diagram, the voltage and current unbalanced ratios (VUR, AUR) and the calculated unbalanced current through the neutral line. Transient events – dip, swell and outage – are captured with a programmable threshold.

A built-in clock and calendar stamp every reading stored on the SD memory card, with a sampling time from 2 to 7200 seconds. The card can be read directly on a computer and the data opened in Excel for further analysis. The meter can also be ordered without current probes, on special request, for users who intend to use their own probes.

Key Features

  • Analysis of 3 phase multi-power systems: 1P/2W, 1P/3W, 3P/3W, 3P/4W
  • Measures V (phase-to-phase), V (phase-to-ground), A (phase-to-ground), KW / KVA / KVAR / PF per phase and for the system, KWH / KVAH / KVARH / PFH for the system, and phase angle
  • Harmonics display (1-50th order), with simultaneous display of harmonics and waveform
  • Display of waveform with peak values and analysis of Total Harmonic Distortion (THD)
  • Graphic phase diagram with 3-phase system parameters
  • 3 phase voltage or current unbalanced ratio (VUR, AUR) and unbalanced factor; calculated unbalanced current through the neutral line (An)
  • Captures transient events (dip, swell and outage) with programmable threshold (%)
  • Programmable CT ratio (1 to 600) and PT ratio (1 to 1000)
  • 3 current probes (CP-1201) included; no calibration procedure is needed when the current probes are changed
  • Selectable current probe input signal (200 mV/300 mV/500 mV/1 V/2 V/3 V), so the meter can work with universal current probes
  • Built-in clock and calendar; real time data recording to SD memory card, sampling time 2 to 7200 seconds, with files that open directly in Excel
  • ACV input impedance 10 Mega ohms; safety standard IEC 1010, CAT III 600V
  • Powered by 8 AA (UM-3) DC 1.5 V batteries or a DC 9V adapter
  • Computer data output through the optional USB cable USB-01 or RS232 cable UPCB-02 and Data Acquisition software

Package Contents

  • Instruction manual – 1 PC
  • Test leads (TL88-4AT) – 1 set (4 PCs)
  • Alligator clips (TL88-4AC) – 1 set (4 PCs)
  • Clamp probe (CP-1201) – 3 PCs
  • AC to DC 9V adapter – 1 PC
  • SD memory card – 1 PC
  • Carrying bag – 1 PC

Optional Accessories

  • 2000 Amp current probe, CP-2000
  • 200 Amp current probe, CP-200
  • Flexible 3000 Amp current probe, CP-3000, CP-3002
  • USB cable, USB-01
  • RS232 cable, UPCB-02
  • Data Acquisition software, SW-U811

Product Specifications

ManufacturerLutron Electronic
ModelDW-6195
Wire connections1P/2W, 1P/3W, 3P/3W, 3P/4W
MeasurementsV (phase-to-phase), V (phase-to-ground), A (phase-to-ground); KW / KVA / KVAR / PF (phase); KW / KVA / KVAR / PF (system); KWH / KVAH / KVARH / PFH (system); power factor; phase angle; frequency; harmonics
DisplayTFT LCD, 320 X 240 pixels, with back light; LCD size 81.4 X 54 mm (3.2 X 2.1 inch)
AC voltage (ACV) range10.0 V to 600.0 V, phase to neutral line and phase to phase, auto range
AC voltage resolution0.1 V
AC voltage accuracy±(0.5%+0.5V)
AC current (ACA) 20 A rangeResolution 0.001 A (< 10 A), 0.01 A (≥ 10 A); accuracy: meter + CP-1201 ±(1%+0.1A), meter only ±(0.5%+0.02A)
AC current (ACA) 200 A rangeResolution 0.01 A (< 100 A), 0.1 A (≥ 100 A); accuracy: meter + CP-1201 ±(1%+0.5A), meter only ±(0.5%+0.2A)
AC current (ACA) 1200 A rangeResolution 0.1 A (< 1000 A), 1 A (≥ 1000 A); accuracy: meter + CP-1201 ±(1%+5A), meter only ±(0.5%+2A)
Current probe input signal (ACV)200 mV/300 mV/500 mV/1 V/2 V/3 V
Current probe input current ranges (ACA)20 A/200 A/2000 A (1200 A)/30 A/300 A/3000 A/60 A/600 A/6000 A; the meter can cooperate with universal current probes
Range selectACV: auto range; ACA: manual range
Power factorRange 0.00 to 1.00; resolution 0.01; accuracy ±0.04
Phase angle (Φ)Range -180° to 180°; resolution 0.1°; accuracy ±1°
FrequencyRange 45 to 65 Hz; resolution 0.1 Hz; system accuracy ±0.1 Hz
Active (real) power – range and system accuracy0.000 to 9.999 KW: ±(1.2%+0.008 KW); 10.00 to 99.99 KW: ±(1.2%+0.08 KW); 100.0 to 999.9 KW: ±(1.2%+0.8 KW); 1.000 to 9.999 MW: ±(1.2%+0.008 MW)
Active (real) power – resolution0.000 to 9.999 KW: 0.001/0.01/0.1 KW; 10.00 to 99.99 KW: 0.01/0.1 KW; 100.0 to 999.9 KW: 0.1 KW; 1.000 to 9.999 MW: 0.001 MW (the resolution changes according to the ACA range)
Apparent power – range and system accuracy0.000 to 9.999 KVA: ±(1.2%+0.008 KVA); 10.00 to 99.99 KVA: ±(1.2%+0.08 KVA); 100.0 to 999.9 KVA: ±(1.2%+0.8 KVA); 1.000 to 9.999 MVA: ±(1.2%+0.008 MVA)
Apparent power – resolution0.000 to 9.999 KVA: 0.001/0.01/0.1 KVA; 10.00 to 99.99 KVA: 0.01/0.1 KVA; 100.0 to 999.9 KVA: 0.1 KVA; 1.000 to 9.999 MVA: 0.001 MVA (the resolution changes according to the ACA range)
Reactive power – range and accuracy0.000 to 9.999 KVAR: ±(1.2%+0.008 KVAR); 10.00 to 99.99 KVAR: ±(1.2%+0.08 KVAR); 100.0 to 999.9 KVAR: ±(1.2%+0.8 KVAR); 1.000 to 9.999 MVAR: ±(1.2%+0.008 MVAR)
Reactive power – resolution0.000 to 9.999 KVAR: 0.001/0.01/0.1 KVAR; 10.00 to 99.99 KVAR: 0.01/0.1 KVAR; 100.0 to 999.9 KVAR: 0.1 KVAR; 1.000 to 9.999 MVAR: 0.001 MVAR (the resolution changes according to the ACA range)
Watt hour (active power hour, WH) – range and system accuracy0.000 to 9.999 KWH: ±(2%+0.008 KWH); 10.00 to 99.99 KWH: ±(2%+0.08 KWH); 100.0 to 999.9 KWH: ±(2%+0.8 KWH); 1.000 to 9.999 MWH: ±(2%+0.008 MWH)
Watt hour (WH) – resolution0.000 to 9.999 KWH: 0.001 KWH; 10.00 to 99.99 KWH: 0.01 KWH; 100.0 to 999.9 KWH: 0.1 KWH; 1.000 to 9.999 MWH: 0.001 MWH
VA hour (apparent power hour, SH) – range and system accuracy0.000 to 9.999 KVAH: ±(2%+0.008 KVAH); 10.00 to 99.99 KVAH: ±(2%+0.08 KVAH); 100.0 to 999.9 KVAH: ±(2%+0.8 KVAH); 1.000 to 9.999 MVAH: ±(2%+0.008 MVAH)
VA hour (SH) – resolution0.000 to 9.999 KVAH: 0.001 KVAH; 10.00 to 99.99 KVAH: 0.01 KVAH; 100.0 to 999.9 KVAH: 0.1 KVAH; 1.000 to 9.999 MVAH: 0.001 MVAH
VAR hour (reactive power hour, QH) – range and system accuracy0.000 to 9.999 KVARH: ±(2%+0.008 KVARH); 10.00 to 99.99 KVARH: ±(2%+0.08 KVARH); 100.0 to 999.9 KVARH: ±(2%+0.8 KVARH); 1.000 to 9.999 MVARH: ±(2%+0.008 MVARH)
VAR hour (QH) – resolution0.000 to 9.999 KVARH: 0.001 KVARH; 10.00 to 99.99 KVARH: 0.01 KVARH; 100.0 to 999.9 KVARH: 0.1 KVARH; 1.000 to 9.999 MVARH: 0.001 MVARH
Harmonics display1-50th order; fundamental frequency 50 Hz, 60 Hz
Harmonics of AC voltage in magnitudeResolution 0.1 V; system accuracy: 1 to 20th ±(2%+0.5V); 21 to 30th ±(4%+0.5V); 31 to 50th reference
Harmonics of AC voltage in percentageResolution 0.1 %; accuracy: 1 to 20th ±(2%+10d); 21 to 30th ±(4%+20d); 31 to 50th reference
Harmonics of AC current in magnitudeResolution 0.1 A; system accuracy: 1 to 20th ±(2%+0.5A); 21 to 30th ±(4%+0.5A); 31 to 50th reference
Harmonics of AC current in percentageResolution 0.1 %; system accuracy: 1 to 20th ±(2%+10d); 21 to 30th ±(4%+20d); 31 to 50th reference
Total harmonic distortion (THD)Resolution 0.1 %; system accuracy: 0 to 20 % ±(2%+5d); 20.1 to 100 % ±(6%+10d)
Crest factor of ACV or ACARange 1.000 - 99.99; resolution 0.001; system accuracy ±(5%+30d)
Peak value of ACV or ACASystem accuracy ±(5%+30d)
Programmable CT / PT ratioCT ratio 1 to 600; PT ratio 1 to 1000
ACV input impedance10 Mega ohms
Clamp frequency response40 Hz to 1 KHz
Spec. tested frequency45 to 65 Hz
Overload protectionACV: 720 ACV rms; ACA: 1300 ACA with clamp probe (CP-1201)
Sampling timeApprox. 1 second
Data loggerReal time recording to SD memory card with year/month/date/hour/minute/second; sampling time 2 seconds to 7200 seconds in steps of 2 seconds
Data outputRS232/USB computer interface (optional USB cable USB-01 or RS232 cable UPCB-02)
Data holdFreezes the display reading
Safety standardIEC1010 CAT III 600 V
CertificationsISO-9001, CE, IEC1010
Operating temperature0 to 50 °C (32 to 122 °F)
Operating humidityLess than 80% R.H.
Power supplyDC 1.5 V AA (UM-3) battery X 8 PCs (alkaline or heavy-duty battery), or AC to DC 9V power adapter
Power consumptionMeter: 362 DCmA; clamp: 22 DCmA
Clamp max. conductor size (CP-1201)50 mm (2.0 inch) dia.
DimensionsMeter: 225 X 125 X 64 mm (8.86 X 4.92 X 2.52 inch); clamp: 210 X 64 X 33 mm (8.3 X 2.5 X 1.3 inch); clamp jaw: 86 mm (3.4 inch) outside
WeightMeter: 840 g (meter only); clamp (including cable): 500 g

Write a Review