Lutron YK-2001PHA is a handheld multi-purpose water meter for pH/ORP, conductivity/TDS, salt and dissolved oxygen. It is supplied with the CDPB-03 conductivity/TDS/salt probe; pH, ORP, ATC and oxygen probes are optional. Backlit LCD, data hold, max/min record and RS232/USB output.
The Lutron YK-2001PHA is one handheld meter for multi-purpose water measurement: pH/ORP, conductivity/TDS, dissolved oxygen and salt. It measures pH from 0 to 14.00 pH, ORP within ± 1999 mV, conductivity in four ranges (200 uS / 2 mS / 20 mS / 200 mS), dissolved oxygen from 0 to 20.0 mg/L and salt from 0 to 12 % salt (% weight).
Each quantity is measured with its own separate probe, which makes the meter easy to use in different measurement environments. The Conductivity/TDS/Salt probe CDPB-03 is included; the pH electrode, ORP electrode, ATC temperature probe and dissolved oxygen probe are optional. The dissolved oxygen function uses a polarographic type oxygen probe with a built-in temperature sensor, automatic temperature compensation and adjustable "% SALT" and "Mountain Height" compensation values.
The meter is built around a microcomputer circuit and has an LCD with green backlight, data hold, maximum and minimum recording and an RS232/USB PC computer interface. It is powered by a DC 9V (006 P) battery or a DC 9V adapter.
| Manufacturer | Lutron Electronic |
|---|---|
| Model | YK-2001PHA |
| Measurement functions | pH/ORP, Conductivity/TDS (Total Dissolved Solids), Dissolved Oxygen, Salt |
| pH range | 0 to 14 pH |
| pH resolution | 0.01 pH |
| pH accuracy | ± (0.02 pH + 2 d) – based on calibrated meter only |
| ORP (mV) range | -1999 mV to 1999 mV |
| ORP resolution | 1 mV |
| ORP accuracy | ± (0.5% + 2 d) |
| pH/mV input impedance | 10^12 ohm |
| pH electrode | Optional – any pH electrode with BNC connector |
| pH temperature compensation | Manual: 0 to 100 °C, adjusted by push button on front panel. Automatic (ATC): 0 to 65 °C with the optional temperature probe TP-07 |
| pH calibration | pH7, pH4 and pH10, 3 points calibration |
| Conductivity ranges / resolution | 200 uS: 0 to 200.0 uS / 0.1 uS; 2 mS: 0.2 to 2.000 mS / 0.001 mS; 20 mS: 2 to 20.00 mS / 0.01 mS; 200 mS: 20 to 200.0 mS / 0.1 mS |
| Conductivity accuracy | ± (2 % F.S. + 1 d) @ 23 ± 5 °C; specified for measurement values ≤ 100 mS (F.S. = full scale) |
| TDS ranges / resolution | 200 PPM: 0 to 132 PPM / 0.1 PPM; 2,000 PPM: 132 to 1,320 PPM / 1 PPM; 20,000 PPM: 1,320 to 13,200 PPM / 10 PPM; 200,000 PPM: 13,200 to 132,000 PPM / 100 PPM |
| TDS accuracy | ± (2% F.S. + 1 d) @ 23 ± 5 °C; specified for measurement values ≤ 66,000 PPM |
| Temperature (conductivity probe) | 0 to 60 °C / 32 to 140 °F; resolution 0.1 °C / 0.1 °F; accuracy ± 0.8 °C / ± 1.5 °F @ 23 ± 5 °C |
| Salt range | 0 to 12 % salt (% weight) |
| Salt resolution | 0.01 % salt |
| Salt accuracy | ± 0.5 % salt value |
| Conductivity/TDS/Salt temperature compensation | Automatic from 0 to 60 °C (32 - 140 °F), with temperature compensation factor variable between 0 to 5.0% per °C |
| Conductivity/TDS/Salt probe | CDPB-03 (included), carbon rod electrode for long life; probe operating temperature 0 to 60 °C; round, 22 mm Dia. x 120 mm length |
| Dissolved oxygen range | 0 to 20.0 mg/L |
| Dissolved oxygen resolution | 0.1 mg/L |
| Dissolved oxygen accuracy | ± 0.4 mg/L (23 ± 5 °C) |
| Oxygen in air | 0 to 100.0 %; resolution 0.1 % O2; accuracy ± 0.7% O2 |
| Temperature (oxygen probe) | 0 to 50 °C; resolution 0.1 °C; accuracy ± 0.8 °C / 1.5 °F |
| Dissolved oxygen compensation & adjustment | Temperature: 0 to 50 °C, automatic; Salt: 0 to 50 % Salt; Height: 0 to 8900 meter |
| Oxygen probe | Optional, OXPB-11, polarographic type; probe size 190 mm x 28 mm Dia. (7.5" x 1.1" Dia.); probe weight 335 g/0.74 LB |
| Display | LCD, 52 mm x 38 mm, with green backlight (ON/OFF) |
| Circuit | Custom one-chip of microprocessor LSI circuit |
| Advanced settings | Auto power OFF management; beep sound ON/OFF; temperature unit °C or °F; DO salt % compensation value; DO height (meter) compensation value; CD temperature compensation factor; CD to TDS or TDS to CD, CD only; pH manual temperature compensation value |
| Data hold | Freezes the display reading |
| Memory recall | Maximum & minimum value |
| Sampling time of display | Approx. 1 second |
| Data output | RS 232/USB PC computer interface (optional RS232 cable UPCB-02 or optional USB cable USB-01) |
| Operating temperature | 0 to 50 °C |
| Operating humidity | Less than 85% R.H. |
| Power supply | Alkaline or heavy duty DC 9V (006 P) battery or equivalent; DC 9V adapter input (AC/DC power adapter is optional) |
| Power current | Normal operation (LCD backlight OFF): approx. DC 14 mA; with LCD backlight on, consumption increases approx. 12 mA |
| Standards | ISO-9001, CE, IEC1010 |
| Dimensions | 177 x 68 x 45 mm (7.0 x 2.7 x 1.9 inch) |
| Weight | 489 g/1.08 LB |