Out of Stock
Environmental & Temperature

Wintact WT8811 Compound Gas Monitor for Combustible Gas (LEL), O2, H2S and CO with Colour Screen, Sound/Light/Vibration Alarm and Data Recording

Brand: Benetech
Out of Stock

The Wintact WT8811 compound gas monitor measures combustible gas (0~100 %LEL), O2 (0~30 %VOL), H2S (0~100 µmol/mol) and CO (0~1000 µmol/mol) with ≤ ±5 %FS accuracy. Colour screen, sound/light/vibration alarms, 120,000-data recording and a rechargeable 1800 mAh lithium battery.

Wintact WT8811 Compound Gas Monitor

The Wintact WT8811 is a compound gas monitor that measures four gas concentrations in one instrument: combustible gas (0~100 %LEL), oxygen (0~30 %VOL), hydrogen sulfide (0~100 µmol/mol) and carbon monoxide (0~1000 µmol/mol). It uses high-quality gas sensors with good sensitivity and repeatability, an accuracy of ≤ ±5 %FS and a 90% response time of less than 30 seconds.

The colour screen shows either all four readings at once or a single gas with its maximum, minimum and average values (average of the last 4 minutes) together with the high and low alarm limits. Alarm settings are made separately for each sensor, and the light, sound and vibration alarms can each be switched on or off. The instrument continuously records up to 120,000 data, which can be reviewed on the screen as curves.

The shell is made of high-strength engineering plastics and compound non-slip rubber, dust- and explosion-proof, with an alligator clip on the back. According to the manufacturer, the monitor is widely used in petroleum, chemical, environmental protection, metallurgy, refining, gas transmission and distribution, biochemical medicine and agricultural research.

Key Features

  • Four gases simultaneously: combustible gas (LEL), oxygen (O2), hydrogen sulfide (H2S) and carbon monoxide (CO).
  • Colour-screen display with a user-friendly interface in Chinese or English and three backlight brightness levels.
  • Three alarm forms: sound, light and vibration, with high and low alarm values set for each sensor.
  • Data recording and review: continuously records 120,000 data (125 record groups of 1019 data each) with automatic storage at a set interval.
  • Single and multiple measurement interfaces: real-time, maximum, minimum and average values.
  • Rechargeable lithium battery: DC 3.7 V, 1800 mAh; charging time 6~8 h; standby time more than 8 h.
  • Auto power-off function, date and time display and battery level indicator.
  • Sensor calibration interface (for professionals only) with three calibration methods; the calibration period should not exceed one year.
  • Standards: conforms to GB3836.1-2010, GB3836.4-2010, GB15322.3-2003, JJG693-2011, JJG365-2008, JJG695-2003 and JJG915-2008.

Package Contents

  • Compound gas monitor (with alligator clip) × 1
  • Manual × 1
  • Charger × 1
  • Data line × 1
  • Transparent tube × 1
  • Cover (with screws) × 1
  • Packing box × 1

Product Specifications

ManufacturerWintact
ModelWT8811
Product TypeCompound Gas Monitor (four gases)
Measured GasesCombustible gas (LEL), Oxygen (O2), Hydrogen sulfide (H2S), Carbon monoxide (CO)
Combustible Gas (LEL) Range0~100 %LEL
Combustible Gas (LEL) Resolution0.1 %LEL
Oxygen (O2) Range0~30 %VOL
Oxygen (O2) Resolution0.1 %VOL
Hydrogen Sulfide (H2S) Range0~100 µmol/mol
Hydrogen Sulfide (H2S) Resolution0.1 µmol/mol
Carbon Monoxide (CO) Range0~1000 µmol/mol
Carbon Monoxide (CO) Resolution1 µmol/mol
Accuracy≤ ±5 %FS
Response Time (90%)Less than 30 seconds
Indication ModeLCD displays real-time data and system state; LED, sound and vibration alarm indication
DisplayColour screen; Chinese / English interface; three backlight brightness levels
Data RecordingContinuously records 120,000 data; 125 record groups, 1019 data per group; adjustable recording interval (seconds)
Sensor Stabilisation at Power-OnAbout 20 seconds
Operating ConditionsTemperature: -20~50 °C; Humidity: < 95 %RH non-condensing
Storage ConditionsTemperature: -10~55 °C; Humidity: < 85 %RH
Working VoltageDC 3.7 V (lithium battery, capacity 1800 mAh)
Charging Time6~8 h
Standby TimeMore than 8 h (changes slightly with working state)
Recommended Calibration IntervalRegularly; not exceeding one year
StandardsGB3836.1-2010 (Explosive Atmospheres Part 1: General Requirements for Equipment); GB3836.4-2010 (Explosive Atmospheres Part 4: Equipment with Intrinsically Safe "i" Protection); GB15322.3-2003 (Portable Combustible Gas Detectors, 0~100 %LEL); JJG693-2011; JJG365-2008; JJG695-2003; JJG915-2008
Dimensions71 × 153 × 49 mm
Weight218.7 g (with battery)