Out of Stock
Environmental & Temperature

Lutron DT-2336 Multi-Function Tachometer/Stroboscope: Photo 5 to 99,999 RPM, Contact 0.5 to 19,999 RPM, Strobe to 99,990 FPM, Type K and Pt 1000

Brand: Lutron
Out of Stock

The Lutron DT-2336 combines a photo tachometer (5 to 99,999 RPM), a contact tachometer with surface speed, a stroboscope (100 to 99,990 FPM) and Type K and Pt 1000 thermometer inputs in one handheld meter, with ± (0.05 % + 1 digit) tachometer accuracy and Last/Max/Min memory.

Lutron DT-2336 Tachometer / Stroboscope with Type K and Pt 1000 Thermometer

The Lutron DT-2336 is a multi-function handheld instrument that brings five measurements together: a photo tachometer, a contact tachometer, a stroboscope, a Type K thermocouple thermometer and a Pt 1000 Ω thermometer. The photo tachometer reads from 5 to 99,999 RPM using a high-intensity white light beam, with 0.5 RPM resolution below 1,000 RPM and an accuracy of ± (0.05 % + 1 digit). Its typical detecting distance is 50 to 150 mm, up to 300 mm depending on ambient light.

In contact mode, with the supplied cone and funnel RPM adapters, it measures 0.5 to 19,999 RPM, and with the surface speed test wheel it reads linear speed in m/min, ft/min or in/min (0.05 to 1,999.9 m/min). The stroboscope flashes from 100 to 99,990 RPM/FPM, adjusted with a digital rotate knob and ×2, ÷2, + and − buttons, with an accuracy of ± (0.1 % + 2 d).

With an optional probe, the same meter measures temperature: Type K from -100.0 to 1300.0 °C and Pt 1000 Ω from -10 to 70 °C, both with 0.1 °C resolution. The last, maximum and minimum values are stored automatically and recalled with the REC button. The meter runs on four UM3-AA batteries or an optional DC adapter, and an optional USB or RS232 cable with data acquisition software connects it to a PC.

Key Features

  • Five functions in one instrument: photo tachometer, contact tachometer (RPM, m/min, ft/min, in/min), stroboscope, Type K thermometer and Pt 1000 thermometer
  • High-intensity white light beam for the photo tachometer, for safety and lower power consumption
  • Wide tachometer measuring range from 0.5 to 99,999 RPM
  • 0.5 RPM resolution for readings below 1,000 RPM
  • High precision: ± (0.05 % + 1 digit) tachometer accuracy
  • Last, maximum and minimum values stored in memory automatically and recalled with the REC button
  • Large 43 mm x 33 mm, 5-digit LCD display that shows the reading clearly and saves battery energy
  • One-chip microcomputer LSI circuit and quartz crystal time base for accurate measurement and fast sampling
  • Durable, long-lasting components and a strong, lightweight ABS plastic housing for almost maintenance-free use over many years
  • Housing shaped to fit comfortably in either hand

Package Contents

  • Hard carrying case
  • Reflecting tape marks (600 mm)
  • RPM adapter (CONE)
  • RPM adapter (FUNNEL)
  • Surface speed test wheel
  • Operation manual

Optional Accessories

  • AC to DC adapter
  • USB cable (USB-01)
  • RS232 cable (UPCB-02)
  • Data acquisition software (SW-U801-WIN)
  • Excel data acquisition software (SW-E802)
  • Type K temperature probes: TP-01, TP-02A, TP-03, TP-04, TP-05
  • TP-1000 Pt 1000 Ω temperature probe

Product Specifications

ManufacturerLutron
ModelDT-2336
FunctionsPhoto tachometer (RPM); contact tachometer (RPM, m/min, ft/min, in/min); stroboscope; Type K thermometer; Pt 1000 thermometer
Photo Tachometer Range5 to 99,999 RPM
Photo Tachometer Resolution0.5 RPM (< 1,000 RPM); 1 RPM (≥ 1,000 RPM)
Photo Tachometer Accuracy± (0.05 % + 1 digit)
Photo Detecting Distance50 to 150 mm / 2 to 6 inch (typical max. 300 mm / 12 inch, depending upon ambient light); specified with 10 mm square reflecting tape at 1,800 RPM
Contact Tachometer Range0.5 to 19,999 RPM; surface speed 0.05 to 1,999.9 m/min
Contact Tachometer ResolutionRPM: 0.5 RPM (< 1,000 RPM), 1 RPM (≥ 1,000 RPM); m/min: 0.05 m/min (< 100 m/min), 0.1 m/min (≥ 100 m/min); ft/min: 0.1 ft/min (< 1,000 ft/min), 1 ft/min (≥ 1,000 ft/min); in/min: 0.1 in/min (< 1,000 in/min), 1 in/min (≥ 1,000 in/min)
Contact Tachometer Accuracy± (0.05 % + 1 digit); when using the test wheel, accuracy can be affected by as much as 0.5 % of reading
Stroboscope Flash Range100 to 99,990 RPM/FPM
Stroboscope Resolution0.1 RPM (< 1,000 RPM); 1 RPM (1,000 to 30,000 RPM); 5 RPM (30,000 to 50,000 RPM); 10 RPM (50,000 to 99,990 RPM)
Stroboscope Accuracy± (0.1 % + 2 d)
Stroboscope ControlsDigital rotate knob, ×2 button, ÷2 button, + button, − button
Type K Thermometer Range / Accuracy-50.0 to 1300.0 °C: ± (0.4 % + 0.5 °C); -50.1 to -100.0 °C: ± (0.4 % + 1 °C); -58.0 to 2372.0 °F: ± (0.4 % + 1 °F); -58.1 to -148.0 °F: ± (0.4 % + 1.8 °F)
Type K Thermometer Resolution0.1 °C / 0.1 °F
Pt 1000 Ω Thermometer Range-10 to 70 °C / 14 to 158 °F
Pt 1000 Ω Thermometer Resolution0.1 °C / 0.1 °F
Pt 1000 Ω Thermometer Accuracy± 1.2 °C / ± 2.2 °F
Specification ConditionsElectrical specifications at 23 ± 5 °C; tested under RF field strength less than 3 V/M and frequency less than 30 MHz only
Display43 mm x 33 mm LCD, 5 digits, with display unit
MemoryLast / Max. / Min. value
Circuit / Time BaseExclusive one-chip microcomputer LSI circuit; quartz crystal time base
Over Input DisplayIndication of "- - - -"
Operating Temperature0 to 50 °C (32 to 122 °F)
Operating HumidityMax. 80 % RH
Power SupplyUM3-AA x 4 (DC 6 V battery); DC adapter (optional)
Power ConsumptionApprox. DC 42 mA
StandardsISO-9001, CE, IEC1010
DimensionsHWD 207 x 67 x 39 mm (8.15 x 2.63 x 1.53 inch)
Weight230 g / 0.50 LB (meter only)