Environmental & Temperature

Delta-T GP1 7-Channel Data Logger for Soil Moisture & Environmental Monitoring, IP67, 600,000 Readings, 1 s to 24 h Logging, Relay Output

Brand: Delta-T
Out of Stock

The Delta-T GP1 is a compact, weatherproof, research-grade data logger with 7 channels: 2 differential voltage, 2 temperature, 2 pulse counters and 1 WET Sensor input, plus a relay output. It stores over 600,000 readings in an IP67 case, runs on a 9 V battery and comes with free DeltaLINK software.

Delta-T GP1 Data Logger

The GP1 from Delta-T Devices is a compact, weatherproof, research-grade data logger. Connected to one or two ThetaProbe (ML3) or SM150T soil moisture sensors, it provides simple, high-accuracy recording of soil moisture content together with rainfall and temperature. Its 7 channels record 2 differential analogue voltages, 2 temperatures, 2 pulse counters and 1 Delta-T WET Sensor, while a versatile relay output can be driven by multiple sensor thresholds to raise alarms, control experimental conditions or control irrigation.

The fully sealed IP67 enclosure (140 x 105 x 45 mm) needs no secondary enclosure for outdoor use, and its small size allows it to be installed in confined spaces or hidden away where security is a concern. The internal 9 V PP3 (6LR61) alkaline battery typically lasts a full year when taking hourly readings; alternatively the logger can be powered from an 11 to 24 V DC external source or from a solar panel. Over 600,000 readings (typical) are held in 1 MB of non-volatile flash memory, so data remain safe even if the battery runs flat.

The free DeltaLINK software supplied with the GP1 provides full configuration, sensor checking with real-time graphing, and data collection; data can be graphed in DeltaLINK or imported into Excel. Data are collected by laptop via RS232 or USB, or remotely through cellular modem options, and with a modem gateway and data package the GP1 can upload to the DeltaLINK-Cloud online platform for remote viewing, dashboards and data sharing. Up to 10 GP1 loggers can be networked over M8 cabling to share power and communications, and GP2 loggers can join such a network via an adapter cable.

Key Features

  • 7 channels: 2 differential voltage, 2 temperature, 2 counters and 1 WET Sensor channel, plus 1 relay output
  • Differential voltage channels: -0.2 V to +2.7 V input range, accuracy ± (0.3 mV + 0.01% reading) typical at +20 °C; ideal for ML3 and SM150T soil moisture sensors, powered by a configurable warm-up from switched battery power or the +5 V reference
  • Temperature channels: optimised for 10K thermistor probes over -20 to +60 °C, ±0.07 °C typical at +20 °C; either channel can instead log an additional SM150T sensor (up to 4 SM150T sensors without temperature probes). These are single-ended inputs, so avoid long cables or noisy environments when using them for soil moisture sensors; the soil moisture accuracy figures do not apply to them
  • Counters: one fast counter for pulses up to 33 kHz and one slow counter; either records switch closures up to 50 Hz, suitable for rain gauges and flow meters
  • WET Sensor channel: water content, electrical conductivity and temperature, with specialist calibrations for mineral wool, peat-based composts and coconut fibre (coir)
  • Bridge sensors: 1 or 2 optional GP-PBA-X50 precision bridge adapters for pressure transducer tensiometers and other bridge sensors; EQ3 sensors can also be logged (up to 2, as mV only)
  • Smart relay control: separate ON / OFF conditions and adjustable ON duty cycle; irrigation can be controlled directly from soil moisture, rainfall and/or temperature, and the output can be pulsed to match the water application rate to the soil's infiltration capacity
  • Logging: 1 second to 24 hours, all sensors recorded at the same rate; specialist configuration programs for irrigation control and for the BF5 Sunshine Sensor and SPN1 Sunshine Pyranometer
  • Logging engine of the WS-GP1 compact weather station

Package Contents

  • GP1 Data Logger
  • DeltaLINK software
  • RS232 cable

Optional Accessories

  • USB-RS232 Adapter Cable – connects to a PC USB port (needed for USB data collection)
  • Mounting Plate type DL-MKT – 320 x 190 mm stainless steel plate with fittings for 51 mm tube or flat surfaces
  • External Power Cable type GP1-EPC1 – for powering from an 11 to 24 V DC source
  • Precision Bridge Adapter Board type GP-PBA-X50 – 1 or 2 per GP1
  • GP1 M8 cabling and network accessories
  • Cellular modem gateways for DeltaLINK-Cloud: 3G-DLC-BX1/SP (with 30 W solar panel) and 3G-DLC-BX1/B, used with a data package

Product Specifications

ManufacturerDelta-T Devices
ModelGP1
Input channels2 differential voltage, 2 temperature, 2 event counters, 1 WET Sensor
Voltage input range-0.2 V to +2.7 V
Voltage accuracy (typical at +20 °C)± (0.3 mV + 0.01% reading), over the full -0.2 V to +2.7 V range
Voltage accuracy (max, -20 to +60 °C)± (1.6 mV + 0.05% reading)
Input voltage limits-2.8 V to +3.6 V, each input signal relative to logger GND; CMRR > 66 dB (78 dB typical)
Soil moisture accuracy (ML3 or SM150T, 0 to 60% θ)±0.06%θ (±0.0006 m³.m⁻³) typical at +20 °C; ±0.3%volθ (±0.003 m³.m⁻³) max at -20 to +60 °C; GP1 accuracy, not including sensor errors
Temperature channelsOptimised for 10K thermistor probes, -20 to +60 °C
Temperature accuracy±0.07 °C typical at +20 °C; ±0.1 °C max (with GP1 below 30 °C if reading -20 to 0 °C); using 10K thermistor, not including sensor errors
Resistance accuracy±0.2% of 2 to 100 kΩ reading (±0.3% max) typical at +20 °C; ±0.5% of 2 to 20 kΩ reading at -20 to +60 °C
Event counter (Event6)< 50 Hz, contact closure or pulse/logic inputs
High speed counter (Event5)< 33 kHz pulse/logic; < 100 Hz contact closure
Counter input levelsLogic low < 1 V, logic high > 1.9 V, maximum ±14 V on Event inputs 5 and 6
Relay channel1 x relay, SPST, < 30 V DC or < 24 V AC, 1 A resettable fuse; separate ON / OFF conditions, adjustable ON duty cycle
Internal battery9 V PP3 alkaline, 1 year typical life (2 x ML3 with 1 second warm-up, 2 x 10k thermistors and rain gauge, logging once per hour)
External power11 to 24 V DC via external M8 connector
Switched sensor powerUp to 120 mA: > 10 V if external power > 13.8 V (switched battery or external power)
+5 V reference5 V ±0.6% typical at +20 °C; 5 V ±1.6% at -20 to +60 °C; switched, up to 50 mA
Logging frequency1 second to 24 hours, user configurable
Sensor warm-upMultiples of 1 second, user configurable
Memory> 600k readings (typical), non-volatile flash memory
CommunicationsRS232 (115 kbaud) via external M8 connector, or USB with USB-RS232 adapter cable
SoftwareDeltaLINK (supplied free)
Environmental protectionWater resistant to IP67 (4 cable glands, connector & case)
Operating temperature-20 to +60 °C
Dimensions140 x 105 x 45 mm
Weight280 g including battery