Delta-T SM150T Soil Moisture and Temperature Sensor, 0 to 100% vol, ±3% Accuracy, 0–1 V Output, IP68 Connector, Buriable, Research Grade

Brand: Delta-T
Out of Stock

The Delta-T SM150T measures volumetric soil water content to ±3% vol and soil temperature to ±0.5 °C. Its rugged body and IP68 connector allow long-term burial, and its simple 0–1 V output connects to data loggers or to a handheld meter for instant moisture readings.

Delta-T SM150T Soil Moisture and Temperature Sensor

The SM150T from Delta-T Devices measures soil moisture content and soil temperature. Its sealed plastic body carries two stainless steel sensing rods that are inserted directly into the soil. The sensor applies a 100 MHz waveform to the rods and detects the permittivity of the surrounding soil, which is dominated by its water content, giving a stable voltage output. Patented sensor electronics produce research grade accuracy of ±3% vol over 0 to 70% vol with exceptional salinity and temperature stability, and the built-in thermistor measures soil temperature to ±0.5 °C over 0 to 40 °C.

The SM150T is a dual-purpose sensor. For installed use it is rugged, weather-proof and can be buried: the industrial rated, UV resistant cable with its waterproof IP68 connector lets the sensor stay in the soil while still permitting easy cable exchange or extension. It can be logged by Delta-T GP1, GP2, DL6 and DL2e data loggers and by other loggers through its simple 0–1 V differential output for moisture and 10 K thermistor for temperature. To measure soil temperature accurately the sensor must be fully buried and connected to a data logger.

For portable use the sensor connects to the HH150 readout meter for instant readings, or to the HH2 Moisture Meter when readings must be stored and transferred to a PC. The HH150 and HH2 meters do not read the SM150T temperature. General calibrations for mineral and organic soils are supplied, and a soil-specific calibration can be carried out when greater accuracy is needed. The signal cable is ordered separately.

Key Features

  • Soil moisture accurate to ±3% vol over 0 to 70% vol; measurement range 0 to 100% vol
  • Built-in soil temperature sensor, ±0.5 °C over 0 to 40 °C
  • Low salinity sensitivity and excellent stability
  • Simple 0 to 1.0 V differential output for soil moisture
  • Low power: 5–14 V supply, about 18 mA for 1 second
  • Rugged, weather-proof and buriable, with a waterproof IP68 M12 connector
  • Minimal soil disturbance; easy installation at depth in augered holes using extension tubes
  • Individual sensors are interchangeable
  • Compatible with HH150 and HH2 meters and GP1, GP2, DL6 and DL2e data loggers
  • General soil calibrations for mineral and organic soils; soil-specific calibration possible

Optional Accessories

  • SMSC/lw-05: 5 m cable with 200 mm flying leads for connection to data loggers and controllers
  • EXT/5W-05, EXT/5W-10, EXT/5W-25: 5 m, 10 m and 25 m logger extension cables (can be joined up to a maximum of 100 m)
  • HH150 readout meter with 1 m cable
  • SMSC/d-HH2: 0.9 m cable for connection to the HH2 Moisture Meter
  • ML/EX50 and ML/EX100: 0.5 m and 1.0 m extension tubes for burial at depth
  • SM-AUG-100: 1.2 m spiral auger

Product Specifications

ManufacturerDelta-T Devices Ltd
ModelSM150T
MeasurementVolumetric water content (soil moisture) and soil temperature
Measuring principle100 MHz waveform applied to a pair of stainless steel rods; soil permittivity converted to a voltage output
Soil moisture measurement range0 to 1.0 m³.m⁻³ (0 to 100% vol), less accurate above 70% vol
Soil moisture accuracy±0.03 m³.m⁻³ (±3% vol) over 0 to 70% vol and 0 to 60 °C
Salinity range50 to 1000 mS.m⁻¹
Salinity error±5% vol over 100 to 1000 mS.m⁻¹ and 0 to 60% vol
Temperature sensor10 K thermistor (10 K resistance at 25 °C)
Temperature sensor accuracy±0.5 °C over 0 to 40 °C (not including logger or cabling error); ±0.75 °C over -20 to +60 °C
Soil moisture output0 to 1.0 V differential, corresponding to 0 to ~0.6 m³.m⁻³ (0 to 60% vol nominal)
Temperature outputResistance: 5.8 kΩ to 28 kΩ
Power requirement5–14 VDC, ~18 mA for 0.5 to 1 s; minimum 5 V with 100 m cable
Maximum cable length100 m (GP1, GP2 and DL6 data loggers; DL2e water content measurement); 25 m (DL2e temperature measurement)
Operating range-20 to +60 °C
Environmental protectionIP68 with Delta-T supplied cables
Cable connectorM12, 5 pin, male, sealed to IP68
Extension tube thread¾ inch BSP
Sample volume~55 x 70 mm diameter, weighted towards the soil immediately surrounding the rods
Compatible meters and loggersHH150 and HH2 meters (soil moisture only); GP1, GP2, DL6 and DL2e data loggers
Sensor calibrationIndividual sensors are interchangeable; recalibration advised every 3 years (depending on use)
Soil calibrationsGeneralised Mineral and Organic soil calibrations are supplied
ComplianceCE; EMC directive 2004/108/EC (EN61326-1:2006); FCC Part 18
DimensionsOverall: 143 x 40 mm diameter; rods: 51 mm x 2.5 mm diameter
Weight77 g (without cable)