Out of Stock
Building & Soil & Surveying

Delta-T PR2/6 Profile Probe for Soil Moisture at 6 Depths (10 to 100 cm), 0 to 0.4 m³.m⁻³ Range, ± 0.04 m³.m⁻³ Accuracy, Analog Output

Brand: Delta-T
Out of Stock

The Delta-T PR2/6 Profile Probe measures volumetric soil moisture at six depths from 10 to 100 cm in one access tube. Read many sites quickly with the HH2 meter or leave it installed on a GP2 or DL6 logger. Accuracy is ± 0.04 m³.m⁻³ after soil-specific calibration.

Delta-T PR2/6 Profile Probe

The PR2/6 Profile Probe from Delta-T Devices measures volumetric soil moisture content at six depths – 10, 20, 30, 40, 60 and 100 cm – from a single access tube. It is a sealed 25.4 mm polycarbonate rod carrying pairs of stainless steel sensing rings. Each pair is driven by a 100 MHz signal whose electromagnetic field extends about 100 mm into the surrounding soil; the soil's permittivity, dominated by its water content, produces a stable analog voltage output for every depth.

The probe serves two purposes: move it from access tube to access tube and read each site in seconds with the HH2 Moisture Meter, or leave it installed on a GP2 or DL6 data logger to follow how soil moisture changes over time. Generalised calibrations for mineral and organic soils are supplied, and a soil-specific calibration can be carried out when higher accuracy is required.

Its patented sensing technology keeps sensitivity to salinity and temperature low, so it reports soil moisture content – not just trends – across a range of soil types, including saline conditions. Access tubes need an installation hole only 27 mm in diameter, which keeps soil disturbance to a minimum.

Key Features

  • Six measurement depths: 10, 20, 30, 40, 60 and 100 cm
  • Soil moisture content – not just trends
  • Low salinity and temperature sensitivity; salinity errors (50 to 400 mS.m⁻¹) are included in the accuracy specification
  • Accuracy ± 0.04 m³.m⁻³ after soil-specific calibration (0 to 40 °C)
  • Portable HH2 meter option for multi-site measurement; GP2 and DL6 logger options for continuous monitoring
  • Full accuracy within 1 s from power-up
  • Environmentally sealed IP68 M12 connector; up to 100 m of cabling
  • Generalised mineral and organic soil calibrations supplied
  • Easy installation in a 27 mm hole with minimal soil disturbance

Package Contents

  • PR2/6 Profile Probe fitted with IP68 connector
  • Protective tube
  • Spare O-rings and centring springs

Optional Accessories

  • HH2 Moisture Meter
  • PRC/d-HH2 1.5 m cable to HH2 meter (cable must be ordered separately)
  • PRC/M12-05 5 m cable to GP2 or DL6 logger; PRC/w-05 5 m cable to bare wire
  • EXT/8W-05, EXT/8W-10 and EXT/8w-25 extension cables (5, 10 and 25 m)
  • ATL1 long access tube with cap, bung and collar
  • PR2-SP spares kit and PR-CB2 carrying bag
  • PR-ASK1-L and PR-AKC1 augering kits; PR-EXK1 extraction kit

Product Specifications

ManufacturerDelta-T Devices Ltd
ModelPR2/6
MeasurementVolumetric soil moisture content θV (m³.m⁻³ or %vol)
Sensors / sensing depths6 sensors at 10, 20, 30, 40, 60 and 100 cm (nominal)
Measurement rangeAccuracy specified from 0 to 0.4 m³.m⁻³; full range 0 to 1.0 m³.m⁻³ (reduced accuracy)
Accuracy± 0.04 m³.m⁻³, 0 to 40 °C, after soil-specific calibration; ± 0.06 m³.m⁻³, 0 to 40 °C, with generalised soil calibration in 'normal' soils
Salinity errorsIncluded in the accuracy figures (50 to 400 mS.m⁻¹)
Soil sampling volumeVertically: ~95% sensitivity within ±50 mm of the upper ring of each pair; horizontally: ~95% sensitivity within a cylinder of 200 mm diameter
Measurement signal100 MHz
StabilisationFull accuracy within 1 s from power-up
Output6 analog voltage outputs, ~0 to 1.0 V DC differential, corresponding to 0 to 0.6 m³.m⁻³ (mineral calibration)
Power requirement5.5 to 15 V DC (minimum 5.5 V with 2 m cable); ~120 mA for 1 s
Soil calibrationsGeneralised mineral and organic soil calibrations supplied; soil-specific calibration possible
ConnectorM12 8-way male, IP68
CablingUp to 100 m of cabling
Operating conditions0 to 40 °C for full accuracy; –20 to 60 °C full operating range; IP67 (when installed in access tube)
Construction25.4 mm polycarbonate tube with pairs of stainless steel rings
Readout / data loggersHH2 Moisture Meter; DL6 logger (1 × PR2/6); GP2 logger (2 × PR2/6); DL2e logger
Access tubeATL1 long access tube, 1154 mm × 28 mm (ordered separately)
ComplianceCE marked; EU EMC Directive 89/336/EEC; FCC Part 18